Easy product returns
- Für Netzteile vorgesehen: 315e/630e/600e/6-750e/1000e/1700e
- Unterstützt bis zu 80 Geräte der 80 Gavita e-series fixtures
Technical specifications
|
EL2 |
Input voltage |
240 Volt AC ±10% |
Power inlet |
Adapter: 100V-240V AC 50/60hz - 15V DC |
Ambient temperature |
0 – 35°C |
External dim connection |
RJ14 (4p4c) |
Dim connections |
2 |
Light control range |
50 - 115% |
Maximal amount of fixtures to each dim connection |
80 |
Maximal amount of B200 boosters to each dim connection |
6 |
Automatic dim and shut down function |
Yes |
Automatic sunrise / sunset function |
Yes |
ECM interface contacts |
2 |
Alarm contacts |
2 (NC / NO) |
Maximal alarm contact voltage |
13,5V |
Maximal alarm contact current |
50mA |
Features and benefits
-
Sunrise / sunset function
-
Independent light cycles
-
Dim and boost function
-
Easy installation
-
Easy programming
-
Non-volatile memory
-
Event logging
-
Automatic dim function
-
Crop protection - automatic shutdown
-
ECM interface contact
-
Alarm contact
Information
Dim and boost function
Now you have full control of the light cycle and the output power of all your fixtures from a single point. You do not need to turn on or adjust each lamp separately.
Independent light cycles on the EL2
Allowing to have 2 different and overlapping cycles to be programmed, for example: 12/12 on channel 1 and 18/6 on channel 2.
Easy installation
Full plug-and-play installation. Each E-series fixture is supplied with all necessary installation cables.
Easy programming
The Master Controllers are extremely easy to set-up. The two-line green OLED display is sharp and easy to read.
You can choose out of 5 different languages.
Non-volatile memory
All master controllers use dependable, non-volatile memory to store user settings. In this way you don't loose your settings during a power outage.
Independent sunrise and sunset function
Allows you to set the rise and fall time (0-30 min) to simulate sunrise and sunset. Now you can choose between 2 different times of sunrise and sunset between the 2 channels
Event logging
All master controllers now have logging functions for high/low temperature, last auto-dim event, last shutdown event and last power loss, including the event’s date and time.
Automatic dim function
Your lamps will automatically dim when your climate control is no longer able to maintain the correct temperature. These features will keep your crop safe.
Crop protection - automatic shutdown
In the event of a cooling or ventilation failure, the main controller automatically turns off the lighting, preventing direct damage to the crop (or plant fire).
ECM interface contact
For the Master Controller Gavita has developed an external contactor module ECM1. Because the Master Controller operates on a low output voltage, there for it needs an external contact module to switch auxiliary devices.
With the ECM1 you can extend the functionality of your Master Controller to switch auxiliary devices such as heaters, dehumidifiers and CO2 equipment when turning the light ON or OFF according to the hours set on the Master Controller.
Alarm contact
The controller has two alarm contacts labeled A-NC (normally closed) and A-NO (normally open). When the temperature is turned off, the sensor fails or there is a power failure. Both pairs of terminals can be connected to an alarm module that send you a text message.
|
EL1 |
EL2 |
EL1F |
EL2F |
Dim connections |
1 |
2 |
1 |
2 |
Light control range (power) |
50 - 115% |
50 - 115% |
50 - 115% |
50 - 115% |
Maximal amount of fixtures |
40 |
80 |
40 |
80 |
Fan control connections |
|
|
1 |
1 |
Maximal amount of fans |
|
|
2 |
4 |
Fan control range (power) |
|
|
10 - 100% |
10 - 100% |
Crop protection - automatic shutdown |
Yes |
Yes |
Yes |
Yes |
Sunrise / sunset function |
Yes |
Yes |
Yes |
Yes |
Suitable for EFM1 fan control option |
|
|
Yes |
Yes |
Suitable for FB1 fan control option |
|
|
Yes |
Yes |
Suitable for ECM1 option |
|
Yes |
|
Yes |
Alarm contact |
|
1 |
|
1 |
Maximal number of B200 booster |
3 |
6 |
3 |
6 |